{"id":2202,"date":"2020-08-04T15:40:05","date_gmt":"2020-08-04T08:40:05","guid":{"rendered":"http:\/\/www.sujipuli-tech.com\/?p=2202"},"modified":"2020-08-05T12:41:13","modified_gmt":"2020-08-05T05:41:13","slug":"zahner-zennium-x","status":"publish","type":"post","link":"http:\/\/www.sujipuli-tech.com\/?p=2202","title":{"rendered":"ZAHNER &#8211; ZENNIUM X"},"content":{"rendered":"\n<h2 class=\"wp-block-heading\"><strong>                        ZENNIUM X<\/strong><\/h2>\n\n\n\n<div style=\"height:23px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" loading=\"lazy\" width=\"1024\" height=\"500\" src=\"http:\/\/www.sujipuli-tech.com\/wp-content\/uploads\/2020\/08\/zennium_x-1024x500.png\" alt=\"\" class=\"wp-image-2203\" srcset=\"http:\/\/www.sujipuli-tech.com\/wp-content\/uploads\/2020\/08\/zennium_x.png 1024w, http:\/\/www.sujipuli-tech.com\/wp-content\/uploads\/2020\/08\/zennium_x-300x146.png 300w, http:\/\/www.sujipuli-tech.com\/wp-content\/uploads\/2020\/08\/zennium_x-768x375.png 768w, http:\/\/www.sujipuli-tech.com\/wp-content\/uploads\/2020\/08\/zennium_x-150x73.png 150w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><figcaption> <br>ZENNIUM X electrochemical workstation with potentiostat <\/figcaption><\/figure>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p>\n\nThe&nbsp;<em><strong>ZENNIUM X<\/strong><\/em>&nbsp;is a modular electrochemical workstation including a potentiostat \/ galvanostat&nbsp; and a frequency response analyzer (FRA) unit with a frequency range up to 12 MHz at \u00b14 A and at a compliance voltage of up to \u00b132 V. With an input impedance of more than 10 T\u03a9 || 5 pF the workstation is suitable for a wide range of electrochemical tasks.<\/p>\n\n\n\n<p>The electrochemical measurement capabilites of the<strong><em>ZENNIUM<\/em>&nbsp;<em>X<\/em><\/strong>&nbsp;workstation can be extented by adding up to ten additional plug-in cards such as EPC42,&nbsp;TEMP\/U or PAD4. For example, the EPC42 allows the&nbsp;<em><strong>ZENNIUM X<\/strong><\/em>&nbsp;to control up to four additional external devices such as power potentiostats of the PP\/XPot-series (boosters) or electrical loads of the EL-series. Thus, our&nbsp;<em><strong>ZENNIUM X&nbsp;<\/strong><\/em>electrochemical workstation is able to provide even more advanced measurement methods and allows us to satisfy any of your electrochemical research requirements. <\/p>\n\n\n\n<div style=\"height:37px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h4 class=\"wp-block-heading\"><strong>Specifications<\/strong><\/h4>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<table class=\"wp-block-table is-style-stripes\"><tbody><tr><td><strong>General<\/strong><\/td><\/tr><tr><td>Overall bandwidth<\/td><td>DC &#8211; 15 MHz<\/td><\/tr><tr><td>ADC resolution<\/td><td>32 bit<\/td><\/tr><tr><td>Harmonic reject<sup>*<\/sup><\/td><td>&gt; 60 dB @ \u00bd full scale<\/td><\/tr><tr><td>Potentiostat  modes<\/td><td>potentiostatic, galvanostatic, <br>pseudo-galvanostatic, rest potential, off<\/td><\/tr><tr><td>Cell  connection<\/td><td>2-, 3-, 4-terminal kelvin<\/td><\/tr><tr><td>Ground  reference<\/td><td>grounded, floating<\/td><\/tr><tr><td>Extension  slots<\/td><td>10<\/td><\/tr><tr><td>PC interface<\/td><td>USB 2.0<\/td><\/tr><tr><td>Dimensions<\/td><td>470 x 160 x 376 mm<\/td><\/tr><tr><td>Weight<\/td><td>13.2 kg<\/td><\/tr><tr><td>Accessories<\/td><td>cell cable set, USB cable, power cord, manual, <br>Testbox, THALES XT Software Suite<\/td><\/tr><tr><td>Power  supply<\/td><td>100\/115\/230VAC, 50\/60Hz<\/td><\/tr><tr><td>Ambient  temperature<\/td><td>+10 \u00b0C to +30 \u00b0C<\/td><\/tr><tr><td>Ambient  humidity<\/td><td>&lt; 60% without derating<\/td><\/tr><\/tbody><\/table>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<table class=\"wp-block-table is-style-stripes\"><tbody><tr><td><strong>Frequency generator &amp; analyzer<\/strong><\/td><\/tr><tr><td>Frequency range<\/td><td>10 \u00b5Hz to 12 MHz<\/td><\/tr><tr><td>Accuracy<sup>*<\/sup><\/td><td>&lt; 0.0025%<\/td><\/tr><tr><td>Resolution<\/td><td>0.0025%, 10000 steps\/decade<\/td><\/tr><\/tbody><\/table>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<table class=\"wp-block-table is-style-stripes\"><tbody><tr><td><strong>Output <br>potentiostatic<\/strong><\/td><\/tr><tr><td>Controlled <br>voltage<\/td><td>&nbsp; \u00b15 V<br>\u00b115 V<\/td><td><br><br><\/td><\/tr><tr><td>Resolution<\/td><td>2.5 nV<br>7.5 nV<\/td><td>&nbsp; 5 V range<br>15 V range<\/td><\/tr><tr><td>Accuracy<sup>*<\/sup><\/td><td>&nbsp; \u00b150 \u00b5V \u00b1 5 ppm of reading<br>\u00b1200 \u00b5V \u00b1 5 ppm of reading<\/td><td>&nbsp; 5 V range<br>15 V range<\/td><\/tr><tr><td>Integral <br>Nonlinearity<sup>*<\/sup><\/td><td>typ. 1 ppm, max. 2 ppm<br>typ. 3 ppm, max. 8 ppm<\/td><td>&nbsp; 5 V range<br>15 V range<\/td><\/tr><tr><td>Compliance <br>voltage<\/td><td>\u00b116 V<br>\u00b132 V<\/td><td>Low compliance <br>voltage mode<br>High&nbsp;compliance&nbsp;<br>voltage&nbsp;mode<\/td><\/tr><tr><td>AC amplitude<\/td><td>0 to 2 V, 18 bit resolution<br>0 to 6 V, 18 bit resolution<\/td><td>&nbsp; 5 V range<br>15 V range<\/td><\/tr><tr><td>Bandwidth<\/td><td>15 MHz @ 33 \u03a9 load<\/td><\/tr><tr><td>IR compensation<\/td><td>auto AC impedance technique<br>range 0 to 10 M\u03a9<br>resolution 0.012%<\/td><td><br><br><\/td><\/tr><tr><td>Small signal rise time<\/td><td>150 ns to 200 \u00b5s in 5 steps<\/td><td>automatic <br>selection<\/td><\/tr><tr><td>Slew rate<sup>*<\/sup><\/td><td>15 MV\/s<\/td><td>&nbsp;<\/td><\/tr><tr><td>Phase shift<sup>*<\/sup><\/td><td>10\u00b0 @ 500 kHz<\/td><td>&nbsp;<\/td><\/tr><\/tbody><\/table>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<table class=\"wp-block-table is-style-stripes\"><tbody><tr><td><strong>Output <br>galvanostatic<\/strong><\/td><\/tr><tr><td>Controlled <br>current<\/td><td>\u00b14 A<\/td><\/tr><tr><td>Current range<\/td><td>\u00b11 nA to \u00b14 A in 12 steps<\/td><td>Main<\/td><\/tr><tr><td>Resolution<\/td><td>32 bit, \u00b10.2 ppb of FS<\/td><\/tr><tr><td>Accuracy<sup>*<\/sup><\/td><td>0.01 % of FS \u00b1 0.025 % of reading<br>0.05 % of FS \u00b1 0.1 % of reading<\/td><td>\u2265 1 \u00b5A to 100 mA<br>&lt; 1 \u00b5A or &gt; 100 mA<\/td><\/tr><\/tbody><\/table>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<table class=\"wp-block-table is-style-stripes\"><tbody><tr><td><strong>Input<\/strong><\/td><\/tr><tr><td>Maximum input <br>voltage<\/td><td>\u00b15.5 V<br>&nbsp;\u00b116 V<\/td><td>&nbsp; 5 V range<br>15 V range<\/td><\/tr><tr><td>Voltage resolution<\/td><td>2.5 nV<br>7.5 nV<\/td><td>&nbsp; 5 V range<br>15 V range<\/td><\/tr><tr><td>Voltage accuracy<sup>*<\/sup><\/td><td>\u00b120 \u00b5V \u00b1 2 ppm of reading<br>\u00b150 \u00b5V \u00b1 5 ppm of reading<\/td><td>&nbsp; 5 V range<br>15 V range<\/td><\/tr><tr><td>Current resolution<\/td><td>\u00b15 aA (32 Bit)<\/td><td>&nbsp;Main \/ <br>HiZ Probe<\/td><\/tr><tr><td>Current accuracy<sup>*<\/sup><\/td><td>\u00b1 0.01% of FS<br>\u00b1 &nbsp; 0.1% of FS<br>\u00b1 &nbsp; 0.1% of FS<br>\u00b1&nbsp;&nbsp; 0.5% of reading, \u00b1 125 fA<\/td><td>1 \u00b5A &#8230; 100 mA<br>100 mA &#8230; 4 A<br>10 nA &#8230; 1 \u00b5A<br>&lt; |1 nA| HiZ <br>Probe<\/td><\/tr><tr><td>Input impedance<sup>*<\/sup><\/td><td>&gt; 10 T\u03a9 || \u00b15 pF (typical)<br>&gt; 1000 T\u03a9 || \u00b11 pF (typical)<\/td><td>Main<br>HiZ Probe<\/td><\/tr><tr><td>Input leakage <br>current<sup>*<\/sup><\/td><td>&lt; |\u00b1 200 fA| typ.<br>&lt; |\u00b1 2 pA| max.<br>&nbsp;&nbsp; |\u00b1 10 fA| typ.<\/td><td>&nbsp;<br><br>HiZ Probe<\/td><\/tr><tr><td>Impedance range<sup>*<\/sup><\/td><td>&nbsp;&nbsp;&nbsp; 1 m\u03a9 to &nbsp; 10 G\u03a9 \/ &nbsp;&nbsp; 1%<br>100 m\u03a9 to&nbsp;&nbsp; 10 M\u03a9 \/ 0.1%<br>100 m\u03a9 to 100 G\u03a9 \/ &nbsp;&nbsp; 2%<br>&nbsp;&nbsp; 10 \u00b5\u03a9 to &nbsp; &nbsp;&nbsp; 1 G\u03a9 \/ &nbsp; 2%<br>&nbsp; &nbsp; 1 m\u03a9 to&nbsp;&nbsp; 10 M\u03a9 \/ 0.2%<\/td><td>Main<br><br>HiZ<br>Gal<br><br><\/td><\/tr><tr><td>Common mode <br>rejection<sup>*<\/sup><\/td><td>&gt; 86 dB @&nbsp;&nbsp; 10 \u00b5Hz to 100 kHz<br>&gt; 66 dB @ 100 kHz to&nbsp;&nbsp; 12 MHz<\/td><td>&nbsp;<\/td><\/tr><tr><td>Input channel <br>phase-tracking <br>accuracy<sup>*<\/sup><\/td><td>&nbsp; \u00b10.05 \u00b0 @&nbsp;&nbsp; 10 \u00b5Hz to 100 kHz<br>\u00b10.125 \u00b0 @ 100 kHz to&nbsp; 12 MHz<\/td><\/tr><tr><td>Equivalent <br>effective <br>input noise<sup>*<\/sup><\/td><td>1 \u00b5V rms \/ 100 fA rms @ 1 mHz to 10&nbsp;Hz<br>10 \u00b5V rms \/ 15 fA rms @ 1 mHz to 10 Hz<\/td><td>Main<br><br>HiZ<\/td><\/tr><\/tbody><\/table>\n\n\n\n<p>\n\n*Preliminary\n\n<\/p>\n\n\n\n<div style=\"height:26px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h4 class=\"wp-block-heading\"><strong> Zennium X Flyer<\/strong><\/h4>\n\n\n\n<p>\n\nDownload the latest information flyer about ZAHNER Zennium X potentiostat&#8230;<br><\/p>\n\n\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" src=\"http:\/\/zahner.de\/images\/pdflogo.gif\" alt=\"PDF-Document\"\/><\/figure>\n\n\n\n<p><a href=\"http:\/\/zahner.de\/pdf\/zennium_x_flyer.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">zennium_x_flyer.pdf (PDF)<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>ZENNIUM X The&nbsp;ZENNIUM X&nbsp;is a modular electrochemical workstation including a potentiostat \/ galvanostat&nbsp; and a frequency response analyzer (FRA) unit with a frequency range up to 12 MHz at \u00b14 A and at a compliance voltage of up to \u00b132 V. With an input impedance of more than 10 T\u03a9 \u2026<\/p>\n<p class=\"continue-reading-button\"> <a class=\"continue-reading-link\" href=\"http:\/\/www.sujipuli-tech.com\/?p=2202\">Continue reading<i class=\"crycon-right-dir\"><\/i><\/a><\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":[],"categories":[1],"tags":[226,228,170,227,112,229],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v19.6 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>ZAHNER - ZENNIUM X - Sujipuli Technology<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"http:\/\/www.sujipuli-tech.com\/?p=2202\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"ZAHNER - ZENNIUM X - Sujipuli Technology\" \/>\n<meta property=\"og:description\" content=\"ZENNIUM X The&nbsp;ZENNIUM X&nbsp;is a modular electrochemical workstation including a potentiostat \/ galvanostat&nbsp; and a frequency response analyzer (FRA) unit with a frequency range up to 12 MHz at \u00b14 A and at a compliance voltage of up to \u00b132 V. With an input impedance of more than 10 T\u03a9 \u2026 Continue reading\" \/>\n<meta property=\"og:url\" content=\"http:\/\/www.sujipuli-tech.com\/?p=2202\" \/>\n<meta property=\"og:site_name\" content=\"Sujipuli Technology\" \/>\n<meta property=\"article:published_time\" content=\"2020-08-04T08:40:05+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2020-08-05T05:41:13+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/www.sujipuli-tech.com\/wp-content\/uploads\/2020\/08\/zennium_x-1024x500.png\" \/>\n<meta name=\"author\" content=\"admin\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"admin\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"http:\/\/www.sujipuli-tech.com\/?p=2202\",\"url\":\"http:\/\/www.sujipuli-tech.com\/?p=2202\",\"name\":\"ZAHNER - ZENNIUM X - Sujipuli Technology\",\"isPartOf\":{\"@id\":\"http:\/\/www.sujipuli-tech.com\/#website\"},\"datePublished\":\"2020-08-04T08:40:05+00:00\",\"dateModified\":\"2020-08-05T05:41:13+00:00\",\"author\":{\"@id\":\"http:\/\/www.sujipuli-tech.com\/#\/schema\/person\/95a2256967c9bcd4787180dcd773cf0d\"},\"breadcrumb\":{\"@id\":\"http:\/\/www.sujipuli-tech.com\/?p=2202#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"http:\/\/www.sujipuli-tech.com\/?p=2202\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"http:\/\/www.sujipuli-tech.com\/?p=2202#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"http:\/\/www.sujipuli-tech.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"ZAHNER &#8211; ZENNIUM X\"}]},{\"@type\":\"WebSite\",\"@id\":\"http:\/\/www.sujipuli-tech.com\/#website\",\"url\":\"http:\/\/www.sujipuli-tech.com\/\",\"name\":\"Sujipuli Technology\",\"description\":\"Scientific &amp; Technology Tools for Human Touch.\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"http:\/\/www.sujipuli-tech.com\/?s={search_term_string}\"},\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"http:\/\/www.sujipuli-tech.com\/#\/schema\/person\/95a2256967c9bcd4787180dcd773cf0d\",\"name\":\"admin\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"http:\/\/www.sujipuli-tech.com\/#\/schema\/person\/image\/\",\"url\":\"http:\/\/0.gravatar.com\/avatar\/3de11c58d94b8df56fecb9f9b2dac8f4?s=96&d=mm&r=g\",\"contentUrl\":\"http:\/\/0.gravatar.com\/avatar\/3de11c58d94b8df56fecb9f9b2dac8f4?s=96&d=mm&r=g\",\"caption\":\"admin\"},\"url\":\"http:\/\/www.sujipuli-tech.com\/?author=1\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"ZAHNER - ZENNIUM X - Sujipuli Technology","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"http:\/\/www.sujipuli-tech.com\/?p=2202","og_locale":"en_US","og_type":"article","og_title":"ZAHNER - ZENNIUM X - Sujipuli Technology","og_description":"ZENNIUM X The&nbsp;ZENNIUM X&nbsp;is a modular electrochemical workstation including a potentiostat \/ galvanostat&nbsp; and a frequency response analyzer (FRA) unit with a frequency range up to 12 MHz at \u00b14 A and at a compliance voltage of up to \u00b132 V. With an input impedance of more than 10 T\u03a9 \u2026 Continue reading","og_url":"http:\/\/www.sujipuli-tech.com\/?p=2202","og_site_name":"Sujipuli Technology","article_published_time":"2020-08-04T08:40:05+00:00","article_modified_time":"2020-08-05T05:41:13+00:00","og_image":[{"url":"http:\/\/www.sujipuli-tech.com\/wp-content\/uploads\/2020\/08\/zennium_x-1024x500.png"}],"author":"admin","twitter_card":"summary_large_image","twitter_misc":{"Written by":"admin","Est. reading time":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"http:\/\/www.sujipuli-tech.com\/?p=2202","url":"http:\/\/www.sujipuli-tech.com\/?p=2202","name":"ZAHNER - ZENNIUM X - Sujipuli Technology","isPartOf":{"@id":"http:\/\/www.sujipuli-tech.com\/#website"},"datePublished":"2020-08-04T08:40:05+00:00","dateModified":"2020-08-05T05:41:13+00:00","author":{"@id":"http:\/\/www.sujipuli-tech.com\/#\/schema\/person\/95a2256967c9bcd4787180dcd773cf0d"},"breadcrumb":{"@id":"http:\/\/www.sujipuli-tech.com\/?p=2202#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["http:\/\/www.sujipuli-tech.com\/?p=2202"]}]},{"@type":"BreadcrumbList","@id":"http:\/\/www.sujipuli-tech.com\/?p=2202#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"http:\/\/www.sujipuli-tech.com\/"},{"@type":"ListItem","position":2,"name":"ZAHNER &#8211; ZENNIUM X"}]},{"@type":"WebSite","@id":"http:\/\/www.sujipuli-tech.com\/#website","url":"http:\/\/www.sujipuli-tech.com\/","name":"Sujipuli Technology","description":"Scientific &amp; Technology Tools for Human Touch.","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"http:\/\/www.sujipuli-tech.com\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"en-US"},{"@type":"Person","@id":"http:\/\/www.sujipuli-tech.com\/#\/schema\/person\/95a2256967c9bcd4787180dcd773cf0d","name":"admin","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"http:\/\/www.sujipuli-tech.com\/#\/schema\/person\/image\/","url":"http:\/\/0.gravatar.com\/avatar\/3de11c58d94b8df56fecb9f9b2dac8f4?s=96&d=mm&r=g","contentUrl":"http:\/\/0.gravatar.com\/avatar\/3de11c58d94b8df56fecb9f9b2dac8f4?s=96&d=mm&r=g","caption":"admin"},"url":"http:\/\/www.sujipuli-tech.com\/?author=1"}]}},"_links":{"self":[{"href":"http:\/\/www.sujipuli-tech.com\/index.php?rest_route=\/wp\/v2\/posts\/2202"}],"collection":[{"href":"http:\/\/www.sujipuli-tech.com\/index.php?rest_route=\/wp\/v2\/posts"}],"about":[{"href":"http:\/\/www.sujipuli-tech.com\/index.php?rest_route=\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"http:\/\/www.sujipuli-tech.com\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"http:\/\/www.sujipuli-tech.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=2202"}],"version-history":[{"count":4,"href":"http:\/\/www.sujipuli-tech.com\/index.php?rest_route=\/wp\/v2\/posts\/2202\/revisions"}],"predecessor-version":[{"id":2220,"href":"http:\/\/www.sujipuli-tech.com\/index.php?rest_route=\/wp\/v2\/posts\/2202\/revisions\/2220"}],"wp:attachment":[{"href":"http:\/\/www.sujipuli-tech.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=2202"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"http:\/\/www.sujipuli-tech.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcategories&post=2202"},{"taxonomy":"post_tag","embeddable":true,"href":"http:\/\/www.sujipuli-tech.com\/index.php?rest_route=%2Fwp%2Fv2%2Ftags&post=2202"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}