{"id":2196,"date":"2020-08-04T14:49:52","date_gmt":"2020-08-04T07:49:52","guid":{"rendered":"http:\/\/www.sujipuli-tech.com\/?p=2196"},"modified":"2020-08-05T13:03:36","modified_gmt":"2020-08-05T06:03:36","slug":"zahner-zennium-pro","status":"publish","type":"post","link":"http:\/\/www.sujipuli-tech.com\/?p=2196","title":{"rendered":"ZAHNER &#8211; ZENNIUM pro"},"content":{"rendered":"\n<p style=\"text-align:center\"><strong>ZAHNER ZENNIUM pro Electrochemical Workstation <\/strong><\/p>\n\n\n\n<p style=\"text-align:center\">The all-purpose instrument   <\/p>\n\n\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" loading=\"lazy\" width=\"768\" height=\"354\" src=\"http:\/\/www.sujipuli-tech.com\/wp-content\/uploads\/2020\/08\/zennium_pro.png\" alt=\"\" class=\"wp-image-2206\" srcset=\"http:\/\/www.sujipuli-tech.com\/wp-content\/uploads\/2020\/08\/zennium_pro.png 768w, http:\/\/www.sujipuli-tech.com\/wp-content\/uploads\/2020\/08\/zennium_pro-300x138.png 300w, http:\/\/www.sujipuli-tech.com\/wp-content\/uploads\/2020\/08\/zennium_pro-150x69.png 150w\" sizes=\"(max-width: 768px) 100vw, 768px\" \/><figcaption> <br>ZENNIUM Pro electrochemical workstation with potentiostat <\/figcaption><\/figure>\n\n\n\n<div style=\"height:38px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p>The ZENNIUM pro is a modular electrochemical workstation including a potentiostat \/ galvanostat  and a frequency response analyzer (FRA) unit with a frequency range up to 8 MHz at \u00b13 A and at a compliance voltage of up to \u00b128 V. With an input impedance of more than 10 T\u03a9 || 5 pF the workstation is suitable for a wide range of electrochemical tasks. <\/p>\n\n\n\n<p>The electrochemical measurement capabilites of the ZENNIUM pro workstation can be extented by adding up to five additional plug-in cards such as TEMP\/U or EPC42. For example, the latter makes it possible to control up to four additional external devices such as power potentiostats of the PP\/XPot-series (boosters) or electrical loads of the EL-series. Thus, our ZENNIUM pro electrochemical workstation is able to provide even more advanced measurement methods and allows us to satisfy any of your electrochemical research requirements.<\/p>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h4 class=\"wp-block-heading\"><strong>Specifications<\/strong><\/h4>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<table class=\"wp-block-table is-style-stripes\"><tbody><tr><td>\n  <strong>General<\/strong>\n  <\/td><td>\n  &nbsp;\n  <\/td><\/tr><tr><td>   Overall <br>   bandwidth   <\/td><td>\n  DC &#8211; 10 MHz\n  <\/td><\/tr><tr><td>\n  ADC resolution\n  <\/td><td>\n  32 bit\n  <\/td><\/tr><tr><td>   Harmonic <br>    reject<sup>*<\/sup>   <\/td><td>\n  &gt; 60 dB @ \u00bd full\n  scale\n  <\/td><\/tr><tr><td>   Potentiostat <br>    modes   <\/td><td>   potentiostatic,   galvanostatic,                                           pseudo-galvanostatic, rest potential, off   <\/td><\/tr><tr><td>   Cell                                     connection   <\/td><td>\n  2-, 3-, 4-terminal\n  kelvin\n  <\/td><\/tr><tr><td>\n  Ground reference\n  <\/td><td>\n  grounded, floating\n  <\/td><\/tr><tr><td>\n  Extension slots\n  <\/td><td>\n  5\n  <\/td><\/tr><tr><td>\n  PC interface\n  <\/td><td>   USB  2.0   <\/td><\/tr><tr><td>\n  Dimensions\n  <\/td><td>\n  364 x 160 x 376 mm\n  <\/td><\/tr><tr><td>\n  Weight\n  <\/td><td>\n  11.4 kg\n  <\/td><\/tr><tr><td>\n  Accessories\n  <\/td><td>\n  2 cell cable sets,\n  USB cable, power cord, manual\n  <\/td><\/tr><tr><td>\n  Power supply\n  <\/td><td>\n  100\/115\/230VAC,\n  50\/60Hz\n  <\/td><\/tr><tr><td>   Ambient <br>   temperature   <\/td><td>\n  +10 \u00b0C to +30 \u00b0C\n  <\/td><\/tr><tr><td>   Ambient <br>   humidity   <\/td><td>\n  &lt; 60% without\n  derating\n  <\/td><\/tr><\/tbody><\/table>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<table class=\"wp-block-table is-style-stripes\"><tbody><tr><td>\n  <strong>Frequency\n  generator &amp; analyzer<\/strong>\n  <\/td><td>\n  &nbsp;\n  <\/td><\/tr><tr><td>\n  Frequency range\n  <\/td><td>\n  10 \u00b5Hz to 8 MHz\n  <\/td><\/tr><tr><td>\n  Accuracy<sup>*<\/sup>\n  <\/td><td>\n  &lt; 0.0025%\n  <\/td><\/tr><tr><td>\n  Resolution\n  <\/td><td>\n  0.0025%, 10000\n  steps\/decade\n  <\/td><\/tr><\/tbody><\/table>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<table class=\"wp-block-table is-style-stripes\"><tbody><tr><td>\n  <strong>Output potentiostatic<\/strong>\n  <\/td><td>\n  &nbsp;\n  <\/td><\/tr><tr><td>\n  Controlled voltage\n  <\/td><td>\n  &nbsp; \u00b15 V<br>\n  \u00b115 V\n  <\/td><\/tr><tr><td>\n  Resolution\n  <\/td><td>   2.5 nV                                             5 V range <br>   7.5 nV                                             15 V range <\/td><\/tr><tr><td>\n  Accuracy<sup>*<\/sup>\n  <\/td><td>   \u00b1100 \u00b5V \u00b1 10 ppm of reading    5 V range <br>   \u00b1500 \u00b5V \u00b1 10 ppm of reading    15 V range <\/td><\/tr><tr><td>\n  Integral Nonlinearity<sup>*<\/sup>\n  <\/td><td>   typ. 2 ppm, max. 4 ppm              5 V range <br>   typ. 6 ppm, max. 12 ppm           15 V range  <\/td><\/tr><tr><td>\n  Compliance voltage\n  <\/td><td>   \u00b114 V         Low compliance voltage mode <br>   \u00b128 V         High compliance voltage mode <\/td><\/tr><tr><td>\n  AC amplitude\n  <\/td><td>   0 to 2 V, 18 bit resolution            5 V range <br>   0 to 6 V, 18 bit resolution           15 V range <\/td><\/tr><tr><td>\n  Bandwidth\n  <\/td><td>\n  10 MHz @ 33 \u03a9 load\n  <\/td><\/tr><tr><td>\n  IR compensation\n  <\/td><td>\n  auto AC impedance technique<br>\n  range 0 to 10 M\u03a9<br>\n  resolution 0.012%\n  <\/td><\/tr><tr><td>\n  Small signal rise time\n  <\/td><td>   150 ns to 200 \u00b5s in 5 steps<br>   automatic selection <\/td><\/tr><tr><td>\n  Slew rate<sup>*<\/sup>\n  <\/td><td>\n  15 MV\/s\n  <\/td><\/tr><tr><td>\n  Phase shift<sup>*<\/sup>\n  <\/td><td>\n  10\u00b0 @ 500 kHz\n  <\/td><\/tr><\/tbody><\/table>\n\n\n\n<div style=\"height:23px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<table class=\"wp-block-table is-style-stripes\"><tbody><tr><td>   <strong>Output <\/strong><br><strong>   galvanostatic<\/strong>   <\/td><td>\n  &nbsp;\n  <\/td><\/tr><tr><td>   Controlled <br>   current   <\/td><td>\n  \u00b13 A\n  <\/td><\/tr><tr><td>\n  Current range\n  <\/td><td>   \u00b11 nA to \u00b13 A in 12 steps&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Main   <\/td><\/tr><tr><td>\n  Resolution\n  <\/td><td>\n  32 bit, \u00b10.2 ppb of FS\n  <\/td><\/tr><tr><td>\n  Accuracy<sup>*<\/sup>\n  <\/td><td>   0.02 % of FS \u00b1 0.05 % of reading&nbsp;&nbsp;&nbsp;\u2265 1 \u00b5A to 100 mA<br>   0.1 % of FS \u00b1 &nbsp; &nbsp; 0.2 % of reading&nbsp;&nbsp;&nbsp;&lt;   1 \u00b5A or &gt; 100 mA   <\/td><\/tr><\/tbody><\/table>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<table class=\"wp-block-table is-style-stripes\"><tbody><tr><td>\n  <strong>Input<\/strong>\n  <\/td><td>\n  &nbsp;\n  <\/td><\/tr><tr><td>   Maximum input  <br>   voltage   <\/td><td>   \u00b15.5 V       5 V range  <br>   \u00b116 V        15 V range <\/td><\/tr><tr><td>\n  Voltage resolution\n  <\/td><td>   2.5 nV       5 V range <br>   7.5 nV       15 V range  <\/td><\/tr><tr><td>\n  Voltage accuracy<sup>*<\/sup>\n  <\/td><td>\u00b150 \u00b5V \u00b1 5   ppm of reading     5 V range <br>\u00b1100 \u00b5V \u00b1 10 ppm of reading  15 V range <\/td><\/tr><tr><td>\n  Current resolution\n  <\/td><td>   \u00b15 aA (32 Bit)      Main \/ HiZ Probe <\/td><\/tr><tr><td>\n  Current accuracy<sup>*<\/sup>\n  <\/td><td>   \u00b1 0.02% of FS     1 \u00b5A &#8230; 100 mA <br>   \u00b1 0.2% of FS       100 mA &#8230; 3 A <br>   \u00b1 0.2% of FS        1 nA &#8230; 1 \u00b5A <br>   \u00b1 0.5% of reading, \u00b1 125 fA   <br>   &lt; |1 nA| (HiZ Probe) <\/td><\/tr><tr><td>\n  Input impedance<sup>*<\/sup>\n  <\/td><td>   &gt; 10 T\u03a9 || \u00b15 pF   (typical)       Main <br>   &gt; 1000 T\u03a9 || \u00b11 pF (typical)     HiZ Probe <\/td><\/tr><tr><td>   Input leakage current<sup>*<\/sup>   <\/td><td>   &lt; |\u00b1 200 fA| typ.<br>   &lt; |\u00b1 2 pA| max.<br>   &nbsp;&nbsp; |\u00b1 10 fA| typ.                            HiZ Probe <\/td><\/tr><tr><td>\n  Impedance range<sup>*<\/sup>\n  <\/td><td>   &nbsp;&nbsp;&nbsp; 1   m\u03a9 to &nbsp; 10 G\u03a9 \/ &nbsp;&nbsp; 2%          Main <br>   100 m\u03a9 to &nbsp; 10 M\u03a9 \/ 0.2%<br>   100 m\u03a9 to 100 G\u03a9 \/ &nbsp;&nbsp; 2%            HiZ <br>   &nbsp;&nbsp; 10 \u00b5\u03a9 to &nbsp;&nbsp;&nbsp; 1 G\u03a9 \/&nbsp;&nbsp;&nbsp; 2%             Gal <br>   &nbsp;&nbsp; 1 m\u03a9 to &nbsp;&nbsp; 10 M\u03a9 \/ 0.2%   <\/td><\/tr><tr><td>   Common mode  <br>    rejection<sup>*<\/sup>   <\/td><td>\n  &gt; 86 dB\n  @&nbsp;&nbsp; 10 \u00b5Hz to 100 kHz<br>\n  &gt; 66 dB @ 100 kHz to &nbsp; &nbsp; 8 MHz\n  <\/td><\/tr><tr><td>   Input channel   <br>   phase-tracking <br>   accuracy<sup>*<\/sup>   <\/td><td>\n  &nbsp; \u00b10.05 \u00b0\n  @&nbsp;&nbsp; 10 \u00b5Hz to 100 kHz<br>\n  \u00b10.125 \u00b0 @ 100 kHz to&nbsp;&nbsp;&nbsp; 8 MHz\n  <\/td><\/tr><tr><td>   Equivalent effective   <br>    input noise<sup>*<\/sup>   <\/td><td>   1 \u00b5V rms \/ 100 fA   rms @ 1 mHz to 10 Hz    <br>   Main<br>   10 \u00b5V rms \/ 15 fA rms @ 1 mHz to 10 Hz        <br>   HiZ Probe <\/td><\/tr><\/tbody><\/table>\n\n\n\n<p>\n\n*Preliminary\n\n<\/p>\n\n\n\n<div style=\"height:51px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h4 class=\"wp-block-heading\"><strong> Zennium pro Flyer<\/strong><\/h4>\n\n\n\n<p>Download the latest information flyer about ZAHNER Zennium pro potentiostat&#8230;<br><\/p>\n\n\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" src=\"http:\/\/zahner.de\/images\/pdflogo.gif\" alt=\"PDF-Document\"\/><\/figure>\n\n\n\n<p><a href=\"http:\/\/zahner.de\/pdf\/zennium_pro_flyer.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">zennium_pro_flyer.pdf (PDF)<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>ZAHNER ZENNIUM pro Electrochemical Workstation The all-purpose instrument The ZENNIUM pro is a modular electrochemical workstation including a potentiostat \/ galvanostat and a frequency response analyzer (FRA) unit with a frequency range up to 8 MHz at \u00b13 A and at a compliance voltage of up to \u00b128 V. With \u2026<\/p>\n<p class=\"continue-reading-button\"> <a class=\"continue-reading-link\" href=\"http:\/\/www.sujipuli-tech.com\/?p=2196\">Continue reading<i class=\"crycon-right-dir\"><\/i><\/a><\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":[],"categories":[1],"tags":[228,170,227,112],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v19.6 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>ZAHNER - ZENNIUM pro - Sujipuli Technology<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"http:\/\/www.sujipuli-tech.com\/?p=2196\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"ZAHNER - ZENNIUM pro - Sujipuli Technology\" \/>\n<meta property=\"og:description\" content=\"ZAHNER ZENNIUM pro Electrochemical Workstation The all-purpose instrument The ZENNIUM pro is a modular electrochemical workstation including a potentiostat \/ galvanostat and a frequency response analyzer (FRA) unit with a frequency range up to 8 MHz at \u00b13 A and at a compliance voltage of up to \u00b128 V. With \u2026 Continue reading\" \/>\n<meta property=\"og:url\" content=\"http:\/\/www.sujipuli-tech.com\/?p=2196\" \/>\n<meta property=\"og:site_name\" content=\"Sujipuli Technology\" \/>\n<meta property=\"article:published_time\" content=\"2020-08-04T07:49:52+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2020-08-05T06:03:36+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/www.sujipuli-tech.com\/wp-content\/uploads\/2020\/08\/zennium_pro.png\" \/>\n<meta name=\"author\" content=\"admin\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"admin\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"http:\/\/www.sujipuli-tech.com\/?p=2196\",\"url\":\"http:\/\/www.sujipuli-tech.com\/?p=2196\",\"name\":\"ZAHNER - ZENNIUM pro - Sujipuli Technology\",\"isPartOf\":{\"@id\":\"http:\/\/www.sujipuli-tech.com\/#website\"},\"datePublished\":\"2020-08-04T07:49:52+00:00\",\"dateModified\":\"2020-08-05T06:03:36+00:00\",\"author\":{\"@id\":\"http:\/\/www.sujipuli-tech.com\/#\/schema\/person\/95a2256967c9bcd4787180dcd773cf0d\"},\"breadcrumb\":{\"@id\":\"http:\/\/www.sujipuli-tech.com\/?p=2196#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"http:\/\/www.sujipuli-tech.com\/?p=2196\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"http:\/\/www.sujipuli-tech.com\/?p=2196#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"http:\/\/www.sujipuli-tech.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"ZAHNER &#8211; ZENNIUM pro\"}]},{\"@type\":\"WebSite\",\"@id\":\"http:\/\/www.sujipuli-tech.com\/#website\",\"url\":\"http:\/\/www.sujipuli-tech.com\/\",\"name\":\"Sujipuli Technology\",\"description\":\"Scientific &amp; Technology Tools for Human Touch.\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"http:\/\/www.sujipuli-tech.com\/?s={search_term_string}\"},\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"http:\/\/www.sujipuli-tech.com\/#\/schema\/person\/95a2256967c9bcd4787180dcd773cf0d\",\"name\":\"admin\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"http:\/\/www.sujipuli-tech.com\/#\/schema\/person\/image\/\",\"url\":\"http:\/\/0.gravatar.com\/avatar\/3de11c58d94b8df56fecb9f9b2dac8f4?s=96&d=mm&r=g\",\"contentUrl\":\"http:\/\/0.gravatar.com\/avatar\/3de11c58d94b8df56fecb9f9b2dac8f4?s=96&d=mm&r=g\",\"caption\":\"admin\"},\"url\":\"http:\/\/www.sujipuli-tech.com\/?author=1\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"ZAHNER - ZENNIUM pro - Sujipuli Technology","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"http:\/\/www.sujipuli-tech.com\/?p=2196","og_locale":"en_US","og_type":"article","og_title":"ZAHNER - ZENNIUM pro - Sujipuli Technology","og_description":"ZAHNER ZENNIUM pro Electrochemical Workstation The all-purpose instrument The ZENNIUM pro is a modular electrochemical workstation including a potentiostat \/ galvanostat and a frequency response analyzer (FRA) unit with a frequency range up to 8 MHz at \u00b13 A and at a compliance voltage of up to \u00b128 V. With \u2026 Continue reading","og_url":"http:\/\/www.sujipuli-tech.com\/?p=2196","og_site_name":"Sujipuli Technology","article_published_time":"2020-08-04T07:49:52+00:00","article_modified_time":"2020-08-05T06:03:36+00:00","og_image":[{"url":"http:\/\/www.sujipuli-tech.com\/wp-content\/uploads\/2020\/08\/zennium_pro.png"}],"author":"admin","twitter_card":"summary_large_image","twitter_misc":{"Written by":"admin","Est. reading time":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"http:\/\/www.sujipuli-tech.com\/?p=2196","url":"http:\/\/www.sujipuli-tech.com\/?p=2196","name":"ZAHNER - ZENNIUM pro - Sujipuli Technology","isPartOf":{"@id":"http:\/\/www.sujipuli-tech.com\/#website"},"datePublished":"2020-08-04T07:49:52+00:00","dateModified":"2020-08-05T06:03:36+00:00","author":{"@id":"http:\/\/www.sujipuli-tech.com\/#\/schema\/person\/95a2256967c9bcd4787180dcd773cf0d"},"breadcrumb":{"@id":"http:\/\/www.sujipuli-tech.com\/?p=2196#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["http:\/\/www.sujipuli-tech.com\/?p=2196"]}]},{"@type":"BreadcrumbList","@id":"http:\/\/www.sujipuli-tech.com\/?p=2196#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"http:\/\/www.sujipuli-tech.com\/"},{"@type":"ListItem","position":2,"name":"ZAHNER &#8211; ZENNIUM pro"}]},{"@type":"WebSite","@id":"http:\/\/www.sujipuli-tech.com\/#website","url":"http:\/\/www.sujipuli-tech.com\/","name":"Sujipuli Technology","description":"Scientific &amp; Technology Tools for Human Touch.","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"http:\/\/www.sujipuli-tech.com\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"en-US"},{"@type":"Person","@id":"http:\/\/www.sujipuli-tech.com\/#\/schema\/person\/95a2256967c9bcd4787180dcd773cf0d","name":"admin","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"http:\/\/www.sujipuli-tech.com\/#\/schema\/person\/image\/","url":"http:\/\/0.gravatar.com\/avatar\/3de11c58d94b8df56fecb9f9b2dac8f4?s=96&d=mm&r=g","contentUrl":"http:\/\/0.gravatar.com\/avatar\/3de11c58d94b8df56fecb9f9b2dac8f4?s=96&d=mm&r=g","caption":"admin"},"url":"http:\/\/www.sujipuli-tech.com\/?author=1"}]}},"_links":{"self":[{"href":"http:\/\/www.sujipuli-tech.com\/index.php?rest_route=\/wp\/v2\/posts\/2196"}],"collection":[{"href":"http:\/\/www.sujipuli-tech.com\/index.php?rest_route=\/wp\/v2\/posts"}],"about":[{"href":"http:\/\/www.sujipuli-tech.com\/index.php?rest_route=\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"http:\/\/www.sujipuli-tech.com\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"http:\/\/www.sujipuli-tech.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=2196"}],"version-history":[{"count":4,"href":"http:\/\/www.sujipuli-tech.com\/index.php?rest_route=\/wp\/v2\/posts\/2196\/revisions"}],"predecessor-version":[{"id":2221,"href":"http:\/\/www.sujipuli-tech.com\/index.php?rest_route=\/wp\/v2\/posts\/2196\/revisions\/2221"}],"wp:attachment":[{"href":"http:\/\/www.sujipuli-tech.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=2196"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"http:\/\/www.sujipuli-tech.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcategories&post=2196"},{"taxonomy":"post_tag","embeddable":true,"href":"http:\/\/www.sujipuli-tech.com\/index.php?rest_route=%2Fwp%2Fv2%2Ftags&post=2196"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}